Thermal only works when conditions do: Illustration
Inspection

Thermal only works when conditions do

A thermal camera shows surface temperature, not water or insulation. Flown at the right time, it points a consultant to wet roof insulation, missing insulation and air leaks. Flown at the wrong time, it shows noise.

What thermal shows

Surface temperature, and what makes it tell a story

An infrared camera measures the heat radiating from a surface and turns it into an image. A radiometric camera stores a temperature value for every pixel, so a thermographer can analyse the file later: adjust the range, measure spot temperatures, correct for emissivity and distance, and compare areas. A non-radiometric camera only gives you a coloured picture. For inspection, we fly radiometric sensors and deliver the radiometric files, not just the coloured JPEGs.

Thermal does not see through walls or roofs. It sees how heat moves to the surface. Wet insulation holds heat longer than dry insulation. A wall with a gap in the insulation loses more heat on a cold night. Air leaking out of a building warms the cladding around the leak. The camera sees the effect, and a trained person works out the cause. That makes thermal a natural partner to a visual roof inspection or a building envelope survey.

That is why conditions are everything. Without a temperature difference driving heat through the assembly, there is no pattern to see. With sun on the surface, the pattern is swamped by solar heating. With wind, surfaces cool evenly and the pattern fades. With a wet surface, evaporation cools everything and hides what is underneath.

Surface temperature, and what makes it tell a story: Illustration
Conditions

What each type of thermal survey needs

What each type of thermal survey needs: Illustration
SurveyTemperature differenceTime of dayWind and moisture
Roof moisture (low-slope membrane roofs)Built up by the roof absorbing heat during a sunny day; wet areas release it more slowly after sunsetAfter sunset on a clear evening following a sunny day, before surfaces reach equilibriumLow wind; roof surface dry, free of ponding, snow and debris; no significant rain in the day or so before
Heat loss and insulation (walls and roofs)A sustained inside-outside difference, commonly around 10 °C or more for several hoursNight or early morning, with no direct sun on the surfaces for several hours beforeLow wind; dry surfaces; HVAC state known and steady
Air leakageInside-outside temperature difference plus a pressure difference, sometimes created with a blower doorHeating season, night or early morningLow wind; coordination with the building operator
Solar panelsCreated by the panels operating under strong sunlightMiddle of a clear dayLow wind; see solar inspection
Standards

Methods your consultant will recognise

Roof moisture surveys are commonly done to ASTM C1153, the standard practice for locating wet insulation in roofing systems using infrared imaging. It calls for suitable weather, a dry roof surface, and verification: thermal anomalies are marked and then confirmed with core samples or moisture readings, because thermal alone is not proof of water. Building envelope work often references ASTM C1060 for insulation in frame buildings, and ISO and Canadian standards cover thermographic qualification of envelopes. Thermographers are typically certified in levels, with higher levels signing interpretation.

We capture to the method your thermographer or roofing consultant specifies, and we tell you plainly when forecast conditions will not meet it. Flying anyway only gives you a file that nobody should rely on.

Methods your consultant will recognise: Illustration
How it is done

A roof moisture survey, step by step

Confirm the roof type

Thermal moisture surveys work best on low-slope membrane roofs with absorbent insulation. Steep-slope roofs, ballasted roofs and some insulation types give weaker or misleading results.

Watch the forecast

We look for a dry, sunny day followed by a clear, calm evening, and hold a backup date.

Plan the night flight

Flights after sunset need the aircraft lit for night operations and a site survey done in daylight. In controlled airspace, authorization is arranged ahead. In the US, Part 107 night rules apply. See Canadian drone rules and US drone rules.

Fly and capture

A mapping grid of the whole roof in thermal, plus a daylight visual set for reference, so every anomaly can be placed on a map.

Mark anomalies

The thermographer outlines suspected wet areas on the thermal orthomosaic.

Verify on the roof

The roofing consultant takes cores or moisture readings at marked areas to confirm. Only then does the repair scope get written.

A roof moisture survey, step by step: Illustration
What goes wrong

Why thermal surveys disappoint

Why thermal surveys disappoint: Illustration

Reflections read as hot spots

Metal flashing, glass and wet membranes reflect sky and surroundings, so the camera reads the reflection, not the surface.

How we handle itAngles are chosen to reduce reflection, and the thermographer checks suspect areas against the visual images. →

A daytime flight for a heat loss job

Sun-loaded walls show the sun, not the insulation.

How we handle itWe schedule heat loss work at night or early morning in the heating season. →

Coloured pictures with no data

A report full of rainbow images that cannot be re-analysed.

How we handle itYou receive the radiometric files in the DroneLink project record, alongside the report images. →
Questions

Questions

Can a drone thermal camera find roof leaks?

It finds areas where insulation under the membrane is likely wet, which is usually where water has entered. Those areas are then confirmed with cores or moisture readings before any repair is planned.

What is the best time of day for a thermal roof inspection?

For roof moisture, after sunset on a clear, calm evening that follows a sunny day, while the roof is releasing the heat it absorbed. For heat loss from a building, at night or early morning in the heating season.

How much temperature difference do you need for thermal imaging of a building?

A sustained difference between inside and outside is needed. Around 10 °C or more held for several hours is a commonly used guide, but your thermographer's method sets the actual requirement.

What is radiometric thermal imaging?

Every pixel carries a temperature value that can be analysed after the flight. Non-radiometric images are just pictures, which makes them much less useful as evidence.

Can thermal imaging see through walls?

No. It sees surface temperature. Patterns on the surface can suggest missing insulation, moisture or air leaks behind it, which a trained thermographer interprets.

Can drones fly thermal inspections at night in Canada?

Yes, when the pilot and aircraft meet the night operation requirements and the site survey and any airspace authorization are in place. The US allows night flights under Part 107 with lighting and training requirements. Check the current rules.

What drives the cost of a drone thermal survey?

Roof or building size, night work, waiting for suitable weather, the level of thermographer reporting, and whether verification cores are part of the scope.

Tell us about your Toronto site.

An address and what you need is enough to start. We reply with what it will take, who will fly it and when.